Delta PD-01 Manual do Utilizador

Consulte online ou descarregue Manual do Utilizador para não Delta PD-01. Delta PD-01 User manual Manual do Utilizador

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
Vista de página 0
Profibus (CME-PD01)
User Manual
Profibus is a registered trademark of Profibus International.
The information supplied by this document is subject to change without notice. No
responsibility or liability for the correctness of the information supplied within this
document is assumed.
Vista de página 0
1 2 3 4 5 6 ... 34 35

Resumo do Conteúdo

Página 1 - User Manual

Profibus (CME-PD01) User Manual Profibus is a registered trademark of Profibus International. The information supplied by this document is sub

Página 2

Chapter 3 Profibus Introduction| CME-PD01 3-2 Revision October 2006, 2006PDD230000133.2 PROFIBUS-DP PROFIBUS-DP is a PROFIBUS communication profile o

Página 3 -

Revision October 2006, 2006PDD23000013 4-1 Chapter 4 Installation Information Please make sure that the power of VFD-E series is OFF before installa

Página 4

Chapter 4 Installation Information| CME-PD01 4-2 Revision October 2006, 2006PDD23000013 Power Supply The power of CME-PD01 is supplied from VFD-E se

Página 5 - Chapter 1 Preface

Revision October 2006, 2006PDD23000013 5-1 Chapter 5 Communication Please make sure that you have read chapter 4 and fully understood the CME-PD01 i

Página 6 - Chapter 1 Preface

Chapter 5 Communication| CME-PD01 5-2 Revision October 2006, 2006PDD23000013 VFD-E type Baud Rate 9600 P09-01=1 RTU 8, N, 2 P09-03=3 Freq. Source

Página 7 - Chapter 2 Overview

Chapter 5 Communication| CME-PD01 Revision October 2006, 2006PDD23000013 5-3NOTE CME-PD01 supports PPO1 and PPO3 structure only. 5.3.2 Extended Con

Página 8 - 2.3 Functionality

Chapter 5 Communication| CME-PD01 5-4 Revision October 2006, 2006PDD23000013 11B:Change direction 00B:1st Accel / Decel time Bit 6~701B:2nd Accel / D

Página 9 - 3.1 PROFIBUS

Chapter 5 Communication| CME-PD01 Revision October 2006, 2006PDD23000013 5-5NOTE Table above is for reference only, please check VFD-E series user m

Página 10 - 3.2 PROFIBUS-DP

Chapter 5 Communication| CME-PD01 5-6 Revision October 2006, 2006PDD23000013Fault numbers for "Cannot process request" response NO. Descri

Página 11 - 4.1 Installation

Chapter 5 Communication| CME-PD01 Revision October 2006, 2006PDD23000013 5-7NOTE In IND, Bit 15 uses a multiplier of 20, so the value of Bit 15 for

Página 12

Table of Contents Chapter 1 Preface ...1-1 1.1 Receiving and Ins

Página 13 - Chapter 5 Communication

Chapter 5 Communication| CME-PD01 5-8 Revision October 2006, 2006PDD23000013 Request Response Word 1 (PKE) 11C2 Word 1 (PKE) 11C2 Word 2 (IND)

Página 14

Chapter 5 Communication| CME-PD01 Revision October 2006, 2006PDD23000013 5-9in decimal, if set Page Select to 14, then the Basic PNU is 29952-14*200

Página 15 - 5.3.2 Extended Configuration

Chapter 5 Communication| CME-PD01 5-10 Revision October 2006, 2006PDD23000013 T1: transmission time between Master and CME-PD01  T2: waiting time f

Página 16

Revision October 2006, 2006PDD23000013 6-1 Chapter 6 Parameters Setting in GSD file 6.1 GSD File A GSD file is a text file used to identify PROFIBUS

Página 17 - 5.3.5.1 PKE

Chapter 6 Parameters Setting in GSD file| CME-PD01 6-2 Revision October 2006, 2006PDD23000013 Auto_Baud_supp = 1 9.6_supp = 1 19

Página 18 - 5.3.5.2 IND

Chapter 6 Parameters Setting in GSD file| CME-PD01 Revision October 2006, 2006PDD23000013 6-3 0x00,0x00,\

Página 19

Chapter 6 Parameters Setting in GSD file| CME-PD01 6-4 Revision October 2006, 2006PDD23000013Unsigned16 0x0000 0-65535 EndExtUserPrmData ExtUserPrmD

Página 20

Chapter 6 Parameters Setting in GSD file| CME-PD01 Revision October 2006, 2006PDD23000013 6-5 Ext_User_Prm_Data_Ref(10) = 6 Ext_User_Prm_Data_Ref(12)

Página 21 - 5.4 CME-PD01 Response Time

Chapter 6 Parameters Setting in GSD file| CME-PD01 6-6 Revision October 2006, 2006PDD23000013Item Name Type Description Default8 Data Output 4

Página 22

Chapter 6 Parameters Setting in GSD file| CME-PD01 Revision October 2006, 2006PDD23000013 6-7 Data Output 4 = 0x2103; dout_len = 0x0003; The MOD

Página 23 - 6.1 GSD File

5.3.5 Accessing Parameters via PKW Area... 5-5 5.3.5.1 PKE...

Página 24

Chapter 6 Parameters Setting in GSD file| CME-PD01 6-8 Revision October 2006, 2006PDD23000013This page intentionally left blank

Página 25

Revision October 2006, 2006PDD23000013 7-1 Chapter 7 Troubleshooting 7.1 LED Displays Two LEDs, SP and NET LED, are used to monitor the CME-PD01 co

Página 26

Chapter 7 Troubleshooting| CME-PD01 7-2 Revision October 2006, 2006PDD23000013  SP LED State Indication Corrective Actions LED is off No power 1

Página 27 - 6.2 Parameters Settings

Chapter 7 Troubleshooting| CME-PD01 Revision October 2006, 2006PDD23000013 7-3 00 – Normal 01 – CRC check error 02 – VFD-E returns error code 03 – Co

Página 28

Chapter 7 Troubleshooting| CME-PD01 7-4 Revision October 2006, 2006PDD23000013 Error Code Description Corrective Actions 01 Illegal command code

Página 29

Revision October 2006, 2006PDD23000013 8-1 Chapter 8 Dimensions 57.3[2.26]59.7[2.35]3.6[0.14]72.2 [2.84]3.5 [0.14]34.8 [1.37]ADDH ADDLSPNETCME-PB0

Página 31 - Chapter 7 Troubleshooting

Revision October 2006, 2006PDD23000013 1-1 Chapter 1 Preface 1.1 Receiving and Inspection All Delta CME-PD01 have gone through rigorous quality cont

Página 32 - 7.2 Diagnostic Data

Chapter 1 Preface| CME-PD01 1-2 Revision October 2006, 2006PDD23000013 This page intentionally left blank

Página 33 - 7.3 Error Codes

Revision October 2006, 2006PDD23000013 2-1 Chapter 2 Overview CME-PD01, defined as a communication module for PROFIBUS-DP, is used to link VFD-E ser

Página 34

Chapter 2 Overview| CME-PD01 2-2 Revision October 2006, 2006PDD23000013 The address in PROFIBUS-DP can be set via two rotary address switches, ADDH

Página 35 - Chapter 8 Dimensions

Revision October 2006, 2006PDD23000013 3-1 Chapter 3 Profibus Introduction 3.1 PROFIBUS PROFIBUS is an international, vendor- independent, opening

Comentários a estes Manuais

Sem comentários