MS210
MS210 DS004 www.mshinetek.com
- 13 -
The above information is the exclusive intellectual property of M-Shine Technologies Corporation and shall not be disclosed, distributed without permission
rom M-
hine.
Manual Reset
TEST
BEEPEN
Manual Reset
TEST
BEEPEN
If BEEP is required for normal
Operations.
If BEEP not is required for
normal Operations.
Figure 5. Manual Reset.
If normal operations do not “BEEP”, BEEPEN may short to GND constantly, and use TEST pin as the reset
pin.
Used SPI Commands
The SPI flash connected must support the following commands:
COMMAND NAME COMMAND
CODE
DESCRIPTION
JEDEC ID 9FH Read the standard size information.
MS210 Checks the 3
rd
byte reply of command 9F as its size
code. The mapping is as below:
Command 0x9F reply 3
rd
byte
Size
0x10 512K Bits
0x11 1M Bits
0x12 2M Bits
0x13 4M Bits
0x14 8M Bits
0x15 16M Bits
0x16 32M Bits
0x17
64M Bits
DS release ABH Read the signature or release from the deep sleep mode.
Read Status
Register
05H Read the 8-bit register to know if busy.