PROFIBUS DP
RTU-PD01 Slave Communication Module
Operation Manual
DVP-0215820-01
Vista de página 0
1 2 3 4 5 6 ... 43 44

Resumo do Conteúdo

Página 1 - PROFIBUS DP

PROFIBUS DP RTU-PD01 Slave Communication Module Operation Manual DVP-0215820-01

Página 2

PROFIBUS DP Slave Communicaion Module RTU-PD01 DVP-PLC Operation Manual 8 7 GSD File The GSD file is a text file and can be used to identify PROFIBUS

Página 3 - Table of Content

PROFIBUS DP Slave Communicaion Module RTU-PD01 DVP-PLC Operation Manual 9Setup item Setting Definition Modbus protocol 7, E, 1 7, O, 1 7, E, 2 7, O,

Página 4 - 1 Introduction to RTU-PD01

PROFIBUS DP Slave Communicaion Module RTU-PD01 DVP-PLC Operation Manual 10 Configuration item Configurable device Configuration method Modbus 1 rea

Página 5

PROFIBUS DP Slave Communicaion Module RTU-PD01 DVP-PLC Operation Manual 11Configuration item Configurable device Configuration method 1 AI 2 AI 4 AI

Página 6 - 3 Installation

PROFIBUS DP Slave Communicaion Module RTU-PD01 DVP-PLC Operation Manual 12 Definitions of configuration items: Parameter Value Definition Location

Página 7

PROFIBUS DP Slave Communicaion Module RTU-PD01 DVP-PLC Operation Manual 13 Definitions of configuration items: Parameter Value Definition Location

Página 8

PROFIBUS DP Slave Communicaion Module RTU-PD01 DVP-PLC Operation Manual 14 Definitions of configuration items: Parameter Value Definition Locatio

Página 9 - Distance (m) 1,200

PROFIBUS DP Slave Communicaion Module RTU-PD01 DVP-PLC Operation Manual 15 z Configuration method for DVP04PT-S Refer to the figure below for the rel

Página 10 - 7 GSD File

PROFIBUS DP Slave Communicaion Module RTU-PD01 DVP-PLC Operation Manual 16 Definitions of configuration items: Parameter Value Definition Locatio

Página 11

PROFIBUS DP Slave Communicaion Module RTU-PD01 DVP-PLC Operation Manual 17z Configuration method for 8AI, 4AI, 2AI and 1AI modules Refer to the figur

Página 13

PROFIBUS DP Slave Communicaion Module RTU-PD01 DVP-PLC Operation Manual 18 z Configuration method for 8AO, 4 AO, 2AO and 1AO modules Refer to the fi

Página 14

PROFIBUS DP Slave Communicaion Module RTU-PD01 DVP-PLC Operation Manual 19z Configuration method for 8AIAO, 4AIAO, 2AIAO and 1AIAO modules Refer to t

Página 15

PROFIBUS DP Slave Communicaion Module RTU-PD01 DVP-PLC Operation Manual 20 Parameter Value Definition Output CR number 1: Master → Slave 0 ~ 48 O

Página 16

PROFIBUS DP Slave Communicaion Module RTU-PD01 DVP-PLC Operation Manual 21Definitions of configuration items: Parameter Value Definition Node ID 1

Página 17

PROFIBUS DP Slave Communicaion Module RTU-PD01 DVP-PLC Operation Manual 22 Definitions of configuration items: Parameter Value Definition Node ID

Página 18

PROFIBUS DP Slave Communicaion Module RTU-PD01 DVP-PLC Operation Manual 23Definitions of configuration items: Parameter Value Definition Node ID 1

Página 19

PROFIBUS DP Slave Communicaion Module RTU-PD01 DVP-PLC Operation Manual 24 LED status Indication How to correct Red light on RTU-PD01 is not connec

Página 20

PROFIBUS DP Slave Communicaion Module RTU-PD01 DVP-PLC Operation Manual 2510 Application Example 1 Mission: Exchanging data between S7-300 (Siemens P

Página 21

PROFIBUS DP Slave Communicaion Module RTU-PD01 DVP-PLC Operation Manual 26 2. Select “File” => “New Project Wizard”. 3. Click “Next” in the

Página 22

PROFIBUS DP Slave Communicaion Module RTU-PD01 DVP-PLC Operation Manual 274. Select “CPU315-2 DP” for CPU as we are using the S7-300 model. Click “Ne

Página 23

PROFIBUS DP Slave Communicaion Module RTU-PD01 DVP-PLC Operation Manual 1 Table of Content 1 Introduction to RTU-PD01...

Página 24

PROFIBUS DP Slave Communicaion Module RTU-PD01 DVP-PLC Operation Manual 28 6. Enter the project name and click “Finish”. 7. A new window will a

Página 25

PROFIBUS DP Slave Communicaion Module RTU-PD01 DVP-PLC Operation Manual 29 2. In the “HW Config” window, double click “DP” in the left-hand side col

Página 26

PROFIBUS DP Slave Communicaion Module RTU-PD01 DVP-PLC Operation Manual 30 3. Click “Properties” in the dialog box, leading to another dialog box.

Página 27 - 10 Application Example 1

PROFIBUS DP Slave Communicaion Module RTU-PD01 DVP-PLC Operation Manual 315. Select communication speed and bus type, then click “OK”. 6. Confir

Página 28 - DVP-PLC Operation Manual

PROFIBUS DP Slave Communicaion Module RTU-PD01 DVP-PLC Operation Manual 32 7. Confirm the information on the PROFIBUS DP bus in the dialog box and c

Página 29

PROFIBUS DP Slave Communicaion Module RTU-PD01 DVP-PLC Operation Manual 33z Add GSD file 1. Select “Options” => “Install New GSD” in the HW Confi

Página 30

PROFIBUS DP Slave Communicaion Module RTU-PD01 DVP-PLC Operation Manual 34 3. We can then see RTU-PD01 in the right-hand side column. RTU-PD01 is th

Página 31

PROFIBUS DP Slave Communicaion Module RTU-PD01 DVP-PLC Operation Manual 352. In the dialog box, select the address of RTU-PD01 slave. The address has

Página 32

PROFIBUS DP Slave Communicaion Module RTU-PD01 DVP-PLC Operation Manual 36 4. Select Slot 0 and double click “DVP16SP11R/T” in the right-hand side c

Página 33

PROFIBUS DP Slave Communicaion Module RTU-PD01 DVP-PLC Operation Manual 37 7. Slot 0 and Slot 1 are for the configuration of digital I/O modules. Th

Página 34

PROFIBUS DP Slave Communicaion Module RTU-PD01 DVP-PLC Operation Manual 2 1 Introduction to RTU-PD01 1.1 Product Introduction 1. Thank you for choo

Página 35

PROFIBUS DP Slave Communicaion Module RTU-PD01 DVP-PLC Operation Manual 38 9. Double click the configured Slot 3 in “HW Config” window to open the

Página 36

PROFIBUS DP Slave Communicaion Module RTU-PD01 DVP-PLC Operation Manual 39 11. After all the configuration items for RTU-PD01 are set, double click t

Página 37

PROFIBUS DP Slave Communicaion Module RTU-PD01 DVP-PLC Operation Manual 40 Data Mapping See the table below for the data mapping relations under th

Página 38

PROFIBUS DP Slave Communicaion Module RTU-PD01 DVP-PLC Operation Manual 41Program Example z When M0.0 = ON, write 1 to Y0 ~ Y7 on DVP16SP and Y0 ~ Y3

Página 39

PROFIBUS DP Slave Communicaion Module RTU-PD01 DVP-PLC Operation Manual 42 MEMO

Página 40

PROFIBUS DP Slave Communicaion Module RTU-PD01 DVP-PLC Operation Manual 32 Profuct Profile and Outline 2.1 Parts and Dimensions 12356987410111213141

Página 41

PROFIBUS DP Slave Communicaion Module RTU-PD01 DVP-PLC Operation Manual 4 Serial transmission speed supported (auto-detection) 9.6kbps; 19.2kbps; 93.

Página 42

PROFIBUS DP Slave Communicaion Module RTU-PD01 DVP-PLC Operation Manual 5 3.3 Installing RTU-PD01 and I/O Module on DIN Rail z Use 35mm DIN rail. z

Página 43

PROFIBUS DP Slave Communicaion Module RTU-PD01 DVP-PLC Operation Manual 6 4 Components 4.1 RUN/STOP Switch Status Description 1. Special I/O module

Página 44

PROFIBUS DP Slave Communicaion Module RTU-PD01 DVP-PLC Operation Manual 75 Establishing PROFIBUS DP Network by RTU-PD01 The right-side interface on R