4. Motion Control Instructions
DVP-MC operating manual 4-149
Parameter
name
Explanation
Data
type
Available
device
Done
When parameter setting is completed,
"Done" turns on; when “Execute” turns off,
"Done" is reset.
BOOL M,Q
Error
When any error is detected, "Error" turns on;
when "Execute" turns off, "Error" is reset.
BOOL M,Q
ErrorID Error code. Please refer to section 5.3. UINT D
Note:
1. The value of "SyncStartPos" in sync area is always greater than "SyncStopPos" in sync area. As
below figure shows, the cutting length is 320; "SyncStartPos" is 310; "SyncStopPos": 10.
2. The limit for sync area is that it must not be larger than the half of cutting length. In above figure,
sync area is 20, and the half of the cutting length is 160.
3. The length parameters in the function are RotaryAxisRadius, FeedAxisRadius, CutLenth,
SyncStartPos, and SyncStopPos with the uniform unit. For example, if the unit for one of the
parameters is CM (centimeter), the units for other parameters must be CM as well.