4-24
Address
Value
Description
14337 9 Number of points in the spline segment.
14338 60000
Point 0 position
14339 60000
Point 1 position
14330 61000
Point 2 position
14331 61500
Point 3 position
14332 61250
Point 4 position
14333 61000
Point 5 position
14334 60750
Point 6 position
14335 61000
Point 7 position
14336 61000
Point 8 position
Downloading with Add Spline Point, Set Spline Interval, and End Spline Segment Commands:
The following commands would be issued in order:
Command
Command
Value
C
0
Clear any pre-existing splines (only needed on
initialization).
T 400
Set the interval for the points that follow to 400
master units.
X
60000
Send leading point.
T
200
Set the interval for the points that follow to 200
master units.
X 60000 Send 1st scanned value.
x 61000 Send 2nd scanned value.
X 61500 Send 3rd scanned value.
x 61250 Send 4th scanned value.
X 61000 Send 5th scanned value.
x 60750 Send 6th scanned value.
T 400
Set the interval for the points that follow to 400
master units.