Delta 28-299A Instruções de Operação Página 23

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
  • Página
    / 77
  • Índice
  • MARCADORES
  • Avaliado. / 5. Com base em avaliações de clientes
Vista de página 22
C
CAUTION
Power factor correction capacitors must be connected to the
input side of the soft starter. Connecting
power factor
correction capacitors to the output side will damage the soft
starter.
4.10 Fuses
4.10.1 Power Supply Fuses
Semiconductor fuses can be used for Type 2 coordination
(according to IEC 60947-4-2 standard) and to reduce the risk
of damage to SCRs from transient overload currents.
HRC fuses (such as Ferraz AJT fuses) can be used for Type 1
coordination according to IEC 60947-4-2 standard.
NOTE
Adaptive Acceleration Control (AAC) controls the motor's
speed profile, within the programmed time lim
it. This may
result in a higher level of current than traditional control
methods.
For applications using Adaptive Acceleration Control to soft
stop the motor with stop times greater than 30 seconds,
motor branch protection should be selected as follows:
Standard HRC line fuses: Minimum 150% motor full
load current
Motor rated line fuses: Minimum rating 100/150%
motor full load current
Motor control circuit breaker minimum long time
setting: 150% motor full load current
Motor control circuit breaker minimum short time
setting: 400% motor full load current for 30
seconds
Fuses recommendations are calculated for 40r C, up to 1000
m.
NOTE
Fuse selection is based on a 400% FLC start for 20 seconds in
conjunction with standard published star
ts per hour, duty
cycle, 40r C ambient temperature and up to 1000 m altitude.
For installations operati
ng outside these conditions, consult
your local supplier.
NOTE
These fuse tables contain recommendations only, always
consult your local supplier to confirm the sele
ction for your
particular application.
For models marked - there is no suitable fuse.
Electrical Installation MCD 500 Operating Instruction
22 MG.17.K3.02 - VLT
®
is a registered Danfoss trademark
44
Vista de página 22
1 2 ... 18 19 20 21 22 23 24 25 26 27 28 ... 76 77

Comentários a estes Manuais